ALARM SYSTEMS

FIND OUT MORE ABOUT OUR ALARM SYSTEMS

CONTACT US
The basic Climatec alarm system consists of the following

High & low temperature monitoring, using our CLT12 High/Low Alarm Thermostat

Control circuit monitor

Single or three-phase monitoring

Battery back-up - for normal alarm operation during mains failure

Battery back-up monitoring

Audible or visual indication of an alarm situation

Available in 3 versions from single to sixteen alarm circuit inputs

Alarm delay to prevent nuisance alarms

Alarms

The Climatec alarm system can be further expanded to include the following options:

Low level and/or low flow water alarm

High temperature alarm, operating inlet system to a fully open position

Minimum ventilation operation monitor

Individual fan tripped or high fan temperature monitor

240VAC inlet gearbox tripped monitor

Feed weighing system alarm

RCD/RCBO tripped monitor

High CO2 and relative humidity alarms

All Climatec alarm systems are wired in a way that would indicate an alarm situation should a failure in the system occur. Our alarm system can be easily connected to an off-site alarm notification service. This type of service is provided by others.

CONTACT US
Climatec - HC42 Four Zone Min/Max Thermostat
Alarms

HC42 Four Zone Min/Max Thermostat

Monitors temperature in up to 4 zones via independent remote sensors

Zone temperature display via single key press

Adjustable sequential display in all zones using the scan facility

Temperature display in either °C or °F

Min. & max. temperature recall for each zone

Memory can be reset via front panel or external switch

Supplied with: 4x SX Temperature Sensor

Available as: Panel Mount

CONTACT US
Climatec - HC42 Four Zone Min/Max Thermostat
Alarms

HP13 Alarm Thermostat

Monitors temperature in a single zone using a single remote sensor

Large digital display shows the temperature in the zone

Temperature display in either °C or °F

Single relay output for both high and low alarm output

Setpoint and adjustable switching differentials

Indicator lamps show the output of the control

Supplied with: 1x SX Temperature Sensor

Available as: Panel Mount or Surface Mount

CONTACT USDOWNLOAD MANUAL
Climatec - HP13 Alarm Thermostat
Alarms

HP16 Dual Zone Alarm Thermostat

Monitors temperature in two zones via two independant remote sensors

Large display show temperature in the selected zone - via a single key press with indicator light

Temperature display in either °C or °F

Two output relays - one per zone for both high and low alarm output

Setpoints and independently adjustable switching differentials

Indicator lamps show output of the individual controls

Supplied with: 2x SX Temperature Sensors

Available as: Panel Mount or Surface Mount

CONTACT USDOWNLOAD MANUAL
Climatec - HP16 Dual Zone Alarm Thermostat
Carbon Dioxide (CO2)

HP75 CO2 Surveyor

Built in 48 hour min & max. CO2 memory

Built in 90 day min. & max. CO2 memory

Built in power supply for CO2 Sensor

Single relay output for max. CO2 alarm

Available as: Panel Mount or Surface Mount

CONTACT USDOWNLOAD MANUAL
Climatec - HP75 CO2 Surveyor
Alarms

DOL 53 AMMONIA SENSOR

This sensor is specifically designed for continuous measurement of ammonia (NH3) concentration in livestock houses.
This sensor raises an alert to high ammonia levels and enables corrective measures to be taken, i.e., extra ventilation or heating,

Accurate measurements in low and high concentrations
Robust with zero maintenance
Plug and play replacement
Requires no calibration during service life
Can be mounted internally without the need for tubes or pumps